A G-TRAC2 MANUAL
General Manual Revised: 03/15/99
XVIII. ROOM RESET THERMOSTAT OPTIONS...................................................................................................12
M
ODULATING ROOM RESET (CONTINUOUS BLOWER OPERATION ONLY) ............................................................................12
C
ALCULATED DISCHARGE TABLE FOR ROOM AND AMBIENT RESET..................................................................................16
M
ULTIPLE ROOM SENSORS..............................................................................................................................................17
BMS R
ESET (CONTINUOUS BLOWER ONLY) ..................................................................................................................... 17
BMS R
ESET FROM VOLTAGE APPLIED TO + AND –........................................................................................................... 18
BMS C
ALIBRATION ........................................................................................................................................................18
A
MBIENT RESET (DAY MODE ONLY – REQUIRES DIPSWITCH A-2 TO BE ON)....................................................................... 18
M
AKE/BREAK RESETS AND OVERRIDES........................................................................................................................... 19
1. “OR” and “V” Override (Day Only)...................................................................................................................19
2. "X" and "Z" Override (Day and night operation).................................................................................................... 20
3. Linear Ambient Reset (During day and night) – Room Control with Intermittent Blower (During night)................... 22
D
IRECT CONTROL 0 – 10 VDC – (CTRAC, METASYS)....................................................................................................... 22
F
OR DIRECT C-TRAC CONTROL OF THE G-TRAC-2........................................................................................................ 23
F
OR DIRECT 0 – 10 VDC CONTROL.................................................................................................................................23
XIX. CALCULATED SET-POINT READOUT (BASE PLUS CALCULATED)........................................................ 23
XX. DISCHARGE TEMPERATURE READOUT.....................................................................................................24
XXI. DISCHARGE SENSOR READOUTS, CALIBRATION, ETC.......................................................................24
TE6100 R
ESISTANCE’S ...................................................................................................................................................24
TE6000 D
ISCHARGE SENSOR SELF-TEST ......................................................................................................................... 25
S
ENSOR RESISTANCE CHART FOR TE 6100-960 AND TE 6000-960................................................................................... 25
D
ISCHARGE SENSOR CALIBRATION..................................................................................................................................25
D
ISCHARGE SET-POINT CALIBRATION ............................................................................................................................. 25
Johnson Set-Point....................................................................................................................................................... 26
Built In Set-Point........................................................................................................................................................26
R
OOM SENSOR CALIBRATION ..........................................................................................................................................26
BMS C
ALIBRATION AND SET UP .....................................................................................................................................26
XXII. G-TRAC2 SET UP SHEET..............................................................................................................................27
XXIII. BURNER SET UP.............................................................................................................................................28
O
PERATOR CONTROL RULES ...........................................................................................................................................28
M
ANUAL SERVICE MODE ................................................................................................................................................ 28
C
OMBUSTION SET UP...................................................................................................................................................... 29
Pot Position Fine Tuning (Low Fire Rate, Low Fire Air)............................................................................................. 29
4. High Fire Gas and Air........................................................................................................................................29
5. Low Fire Gas Flow Rate.....................................................................................................................................30
6. Low Fire Combustion Air....................................................................................................................................30
P
ROPANE GAS.................................................................................................................................................................31
I
NLET/MANIFOLD PRESSURE SETTINGS............................................................................................................................ 31
XIV. SPECIAL SERVICE NOTES...........................................................................................................................32
O
N BOARD FUSE............................................................................................................................................................. 32
L
OW LIMIT LOCKOUTS....................................................................................................................................................32
F
AILED OPERATION OR SOLID STATE CONTROL CONTACTS BY OTHERS............................................................................ 32
A
IR BALANCING (REFER TO NEXT ITEM). ......................................................................................................................... 32
C
OLD DISCHARGE TEMPERATURE IN COLD WEATHER...................................................................................................... 32
I
GNITION PROBLEMS .......................................................................................................................................................33
R
EGULATOR GAS PRESSURE RESPONSES..........................................................................................................................34
P
ILOT SENSING PROBLEMS.............................................................................................................................................. 34
S
MELL FROM FLUE (PRODUCTS OF COMBUSTION) ............................................................................................................34
W
ATER AND ICE FROM COMBUSTION .............................................................................................................................. 34
B
URNER PULSING, BACKFIRING, EXPLODING, NOISY .......................................................................................................35